Three tips for ssbattery maintenance of Qingdao sured authorized agent
Generally speaking, the ambient temperature is the main factor affecting the life of ssbattery. Here are three tips for battery maintenance.
The ambient temperature of ssbattery is kept at 20 ℃ - 25 ℃, which is the best ambient temperature required by battery manufacturer. The increase of temperature can improve the discharge capacity of the battery, but the cost will greatly shorten the life of the battery.
Regular charging and discharging

The floating charge voltage and discharge voltage of UPS power supply have been adjusted to the rated value when they leave the factory, and the discharge current increases with the increase of load. During operation, the load should be adjusted reasonably, such as controlling the number of computers and other electronic equipment. Generally, the load should not exceed 60% of UPS rated load. In this range, the discharge current of ssbattery will not show excessive discharge.


    


Using the communication function
At present, most large and medium ups have the functions of communication with microcomputer and program control. Install the corresponding software on the microcomputer, connect UPS through serial / parallel port, run the program, then the microcomputer can communicate with ups. Generally, it has the functions of information query, parameter setting, punctuality setting, automatic shutdown and alarm. After information query, it can obtain the input voltage of utility power, output voltage of UPS, load utilization, battery capacity utilization, internal temperature and utility frequency; After parameter setting, the basic characteristics of UPS, battery maintenance time and battery run out alarm can be set. Through these intelligent operations, the use and management of UPS power supply and its ssbattery are greatly facilitated.
Timely replacement of spent / damaged batteries
The number of ssbattery in medium and large UPS power supply generally ranges from 8 to 80, or even more. To meet the requirements of UPS DC power supply, a single battery is connected by circuit to form a battery pack. Performance and quality differences, individual battery performance decline, storage capacity can not meet the requirements and damage in the continuous operation of UPS appear inevitable. Maintenance personnel should check and test each battery when one or more batteries in the battery pack are damaged, so that the damaged batteries can be eliminated. It is forbidden to mix acid proof batteries with sealed batteries and batteries of different specifications. When replacing new batteries, we should strive to buy batteries of the same model from the same manufacturer.

The above are the three tips of ssbattery maintenance summarized by Qingdao sured Xiaobian. In addition, you want to know more about ssbattery, Panasonic battery, Meimei battery, special battery and other products. Please contact us at any time!