The role of Leoch battery authorized by Qingdao Sured in power grid
  In order to ensure the power failure of the power grid, UPS can also be used to continue to provide high-quality power for the computer, especially the backup battery equipment.
When the power supply is not allowed to load, the backup time of UPS battery in the communication room shall be longer than the time from power failure to recovery of generator set or normal power supply. The system is equipped with a generator set. If the leoch battery pack is long, it should be equipped with a battery pack with a longer delay

time. However, it should be realized that UPS is not suitable for the system The internal rectifier can be charged by connecting the large capacity battery pack to the outside, otherwise it should be equipped with an external charger. Due to the high temperature of the battery, the battery will be lost, and the water will lead to the continuous concentration of the electrolyte, so that the battery capacity will become larger. The structure of the board, the size of the discharge current, the temperature and density of the electrolyte are most affected by the charge, the discharge current and the air temperature .


If the charge discharge current is too large, the appearance of the active material on the substrate surface will change, and the capacity will be greatly reduced. The decrease of temperature will lead to poor electrolyte flow, shorten the plate, slow down the chemical change and increase the internal resistance of the battery. If the temperature is reduced
by 1 ° C at 30 ° C, the capacity will decrease by about 1% and the internal resistance will increase.



Therefore, in cold regions, when the temperature is below - 20 ℃, the capacity drops to 60%, the internal resistance increases, the engine often fails to start, and the battery power is often felt. It is easy to produce too much emissions in cold regions, but it is often too high in temperate regions. Therefore, in order to better use the leoch battery, it is necessary to master its use law according to the local climate conditions and actual situation. Capacity shall be in accordance with According to the following standards: the battery pool of electric leoch must supply power to the inverter during standby time, and under load, the voltage of the battery pack shall not be lower than the allowable low
voltage of the inverter. Keep the battery pack close to the ups host, shorten the length of the two lines, increase the cross-sectional area of the connection, and reduce the self inductance of the connection line and the line below the voltage drop. The battery pack can be installed in the battery cabinet or open battery rack, the former is very beautiful. It's neat,But the floor has higher requirements for load bearing. The latter can disperse the load and has good heat dissipation, energy consumption, but covers a large area, dust is easy to collect, bring inconvenience to maintenance.


The above is a brief introduction of the role of Leo ch battery in power grid. In addition, we also represent Panasonic, lc-ssb127cn06, Meimei, Fanfan and other brands of batteries. Customers with demand can call at any time.